HELIOSPlus D 系列 大动态范围积分球光源
系统几乎涵盖所有成像测试要求
l宽带3000K类黑体光谱
l从全日光到夜视亮度的非常宽动态范围
l可手动和自动进行光谱输出控制
HELIOSPlus-DR, D 系列系统是以卤素灯为光源的均匀光源校准系统,它具有极其宽的动态范围。
系统 | 积分球尺寸 (inch) | 开口尺寸 (inch) | 最大亮度 (cd/m2) | 开口端照度 (lux) | CCT范围 | 可变衰减器 | #步数 |
USLR-D20F-NANS-P | 20 | 8 | 24,000 | 78,000 | 3000K +/- 50K | Advanced, VAA | 8.80E+06 |
USLR-D20F-NDNN-P | 20 | 8 | 24,000 | 78,000 | 3000K +/- 50K | Dynamic, VAD | 4.80E+04 |
USLR-D20F-NMNN-P | 20 | 8 | 24,000 | 78,000 | 3000K +/- 50K | Manual, VA-MM | 4.00E+04 |
USLR-D12F-NANS-P | 12 | 4 | 40,000 | 135,000 | 3000K +/- 50K | Advanced, VAA | 6.60E+06 |
USLR-D12L-NANS-P | 12 | 4 | 50,00 | 157,000 | 3000K +/- 50K | Advanced, VAA | 6.60E+06 |
USLR-D12F-NDNN-P | 12 | 4 | 37,500 | 117,750 | 3000K +/- 50K | Dynamic, VAD | 3.60E+04 |
USLR-D12L-NDNN-P | 12 | 4 | 50,000 | 157,00 | 3000K +/- 50K | Dynamic, VAD | 3.60E+04 |
USLR-D12F-NMNN-P | 12 | 4 | 37,500 | 117,750 | 3000K +/- 50K | Manual, VA-MM | 3.00E+04 |
USLR-D12L-NMNN-P | 12 | 4 | 50,000 | 157,00 | 3000K +/- 50K | Manual, VA-MM | 3.00E+04 |
USLR-D08F-NANS-P | 8 | 2 | 60,000 | 188,400 | 3000K +/- 50K | Advanced, VAA | 2.00E+06 |
USLR-D08L-NANS-P | 8 | 2 | 80,000 | 251,200 | 3000K +/- 50K | Advanced, VAA | 2.00E+06 |
USLR-D08F-NDNN-P | 8 | 2 | 60,000 | 188,400 | 3000K +/- 50K | Dynamic, VAD | 2.40E+04 |
USLR-D08L-NDNN-P | 8 | 2 | 80,000 | 251,200 | 3000K +/- 50K | Dynamic, VAD | 2.40E+04 |
USLR-D08F-NMNN-P | 8 | 2 | 60,000 | 188,400 | 3000K +/- 50K | Manual, VA-MM | 2.00E+04 |
USLR-D08L-NMNN-P | 8 | 2 | 80,000 | 251,200 | 3000K +/- 50K | Manual, VA-MM | 2.00E+04 |
备注:根据客户应用和所需的不确定性等级,可能需要自定义校准来表征不同操作条件下的系统。我们的应用工程师很乐意与您讨论这一问题,并帮助自定义完美的系统和校准,以满足您的要求。
满足客户动态范围要求
可变衰减器是实现HELIOS®Plus D Family系统动态范围能力的关键元素。其可在不影响光谱保真度的情况下调整系统的亮度输出。有三种可变衰减器可供选择(VAA, VAD和VAM),具有不同程度的自动化和分辨率性能。

自动化测试程序
使用衰减器、探测器和光谱仪,通过响应式 Hunt & Seek 反馈回路自动化研发测试程序,或在HELIOSense GUI内外实现简单程序的脚本功能。HELIOSense 软件是 HELIOSPlus 组件和系统的主要界面。 它是一种灵活的体系结构,任何内置在Labsphere API (LSAPI)中的硬件都可以在HELIOSPlus系统中识别和使用。